<LOGO>
FM Transmitter Measurement Report
Created: 2024-07-28 16-54-56
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 68 dBuV YLEX
Pilot RDS Phase Difference
7.4 kHz 2.3 kHz 55 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 64 kHz 19077 1,4048
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,8 dBr 3,75 dBr 5,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 16:54, 28.07.2024
RT
"YleX Vii "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6207, 6205, 6201, 6203
FM Scope Max at: 64 kHz MIN: 9 kHz % above 76 kHz: 1,4048 Acquired: 2024/07/28 16.53.52 Total samples: 19077 Equivalent time: 0:15:53 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,2 dBr MIN: 0,8 dBr AVE: 3,75 dBr % above 12,2 dBr: 0,0 Last value: 1,9 dBr (2024/07/28 16.53.51) 16.40 16.42 16.44 16.46 16.48 16.50 16.52 0 2 4 6 Pm [dBr]